Supplier Part Number | Manufacturer Part Number | Price | Stock | Manufacturer | Description | Series | Part Status | Filter Type | Configuration | Voltage - Rated DC | Voltage - Rated AC | Voltage - Rated AC ... | Voltage - Rated AC ... | Current | Frequency - Operating ... | Applications | Approvals | Operating Temperature ... | Mounting Type | Termination Style | Inductance | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
FN3280H-160-40![]() | FN3280H-160-40 |
| Leadtime 2-3 weeks | 0H47B-Y7-QD | LINE FILTER 480VAC 160A CHASS | FN 3280 | Active | Three Phase Wye | Two Stage | - | 480V | 300V | 520V | 160A | DC ~ 60Hz | General Purpose | CSA, ENEC, UR | -25°C ~ 100°C | Chassis Mount | Terminal Post | - | ||||||||||||||
6EN4R-5EZ-TB | 6EN4R-5EZ-TB |
| 16 | 16-UR-IJ | LINE FILTER 440VAC 20A CHASS MNT | TD | Active | Three Phase Delta | Two Stage | - | 440V | - | - | 20A | 50 60Hz | General Purpose | - | - | Chassis Mount | Threaded Post M6 | L1 - 78µH, L2 - 1.6mH | ||||||||||||||
F2800AA10![]() | F2800AA10 |
| Leadtime 2-3 weeks | R76MN-LM-T1G | LINE FILTER 250VAC 10A CHASS MNT | F2800 | Active | Single Phase | Two Stage | - | 250V | - | - | 10A | 50 60Hz | General Purpose | CE, CSA, TUV, UR | - | Chassis Mount | Quick Connect | - | ||||||||||||||
B84312C50B101![]() | B84312C50B101 | 7 | 7OSJ-Y6XU-SU | FILTER COMM LINE EMP 0.1A 100VAC | B84312 | Obsolete | - | - | - | - | - | - | - | - | - | - | - | - | - | - | |||||||||||||||
6609068-5![]() | 6609068-5 |
| Leadtime 2-3 weeks | XYY-9ENC-P3T | LINE FILTER 36A CHASSIS MOUNT | AYA | Active | Three Phase Wye | Single Stage | - | - | 250V | 440V | 36A | 50 60Hz | General Purpose | UR | -10°C ~ 40°C | Chassis Mount | Threaded Post 10-32 | - | ||||||||||||||
B84263D25E13![]() | B84263D25E13 | 7 | 7V1V-TZ-7U | LINE FILTER 100A CHASSIS MOUNT | B84263 | Obsolete | Three Phase Wye | Three Stage | - | - | 250V | 440V | 100A | 50 60Hz | General Purpose | - | -25°C ~ 85°C | Chassis Mount | Threaded Post M6 | - | |||||||||||||||
1600APS12P![]() | 1600APS12P |
| 3 | 3QTV-V8-27 | LINE FILTER 690VAC 1.6KA CHASS | APS | Active | Three Phase Delta | Three Stage | - | 690V | - | - | 1.6kA | 50 60Hz | General Purpose | - | -10°C ~ 50°C | Chassis Mount | Quick Connect | - | ||||||||||||||
L2GBD-A8WY-SDV![]() | L2GBD-A8WY-SDV |
| Leadtime 2-3 weeks | CU5-5HT0-W4 | LINE FILTER 48A CHASSIS MOUNT | FN 5045 | Active | Three Phase Delta | Single Stage | - | - | - | - | 48A | - | Regenerative Motor Drive | cURus | -25°C ~ 70°C | Chassis Mount | Terminal Block | 1.1mH | ||||||||||||||
M67BZ-MWF7-QD![]() | M67BZ-MWF7-QD | Leadtime 2-3 weeks | D2B07-86PF-5S5 | LINE FILTER 250VAC 5A CHASS MNT | 62-MMF | 0 | Single Phase | Two Stage | - | 250V | - | - | 5A | 50 60Hz | General Purpose | - | -25°C ~ 85°C | Chassis Mount | Quick Connect | 2.9mH | |||||||||||||||
FMER-G92S-J517 | FMER-G92S-J517 |
| 6 | 6X-T7-M9 | LINE FILTER 1.2KVDC 150A CHASS | FMER SOL | Active | DC | Single Stage | 1200V 1.2kV | - | - | - | 150A | - | Photovoltaic Inverter | cURus | -40°C ~ 100°C | Chassis Mount | Terminal Post | - | ||||||||||||||
FN3270H-20-29 | FN3270H-20-29 |
| Leadtime 2-3 weeks | Q8JFD-8KQ-D0C | LINE FILTER 480VAC 20A CHASS MNT | FN 3270 | Not For New Designs | Three Phase Delta | Single Stage | - | 480V | 300V | 520V | 20A | DC ~ 60Hz | Inverters, Power Drive Systems | CSA, ENEC, UR | -25°C ~ 100°C | Chassis Mount | Terminal Post | - | ||||||||||||||
OJ-OIS-47![]() | OJ-OIS-47 | Leadtime 2-3 weeks | S2-QTI-6NX | LINE FILTER 250VAC 30A CHASS MNT | 62-PMB | 0 | Single Phase | Single Stage | - | 250V | - | - | 30A | 50 60Hz | General Purpose | - | -25°C ~ 85°C | Chassis Mount | Threaded Post M4 | 1.6mH | |||||||||||||||
L41P-87-FK3![]() | L41P-87-FK3 | Leadtime 2-3 weeks | BM-IJOV-ZO0 | LINE FILTER 250VAC 16A CHASS MNT | B84299K | Obsolete | Three Phase Wye | Single Stage | - | 250V | - | - | 16A | 50 60Hz | General Purpose | - | -25°C ~ 85°C | Chassis Mount | Wire Leads | - | |||||||||||||||
FN2010A-20-08![]() | FN2010A-20-08 |
| 52 | 52T-0K-6WR | LINE FILTER 250VAC 20A CHASS MNT | FN 2010 | Active | Single Phase | Single Stage | - | 250V | - | - | 20A | DC ~ 400Hz | Safety | CSA, ENEC, UR | -25°C ~ 100°C | Chassis Mount | Threaded Post M4 | 600µH | ||||||||||||||
B86305L0035R000![]() | B86305L0035R000 |
| Leadtime 2-3 weeks | SO4-SJ-RW6 | LINE FILTER 520VAC 35A CHASS | B86305 | Active | Three Phase Delta | Single Stage | - | 520V | - | - | 35A | 50 60Hz | General Purpose | - | -25°C ~ 100°C | Chassis Mount | Terminal Block | 840µH | ||||||||||||||
F1399AA02 | F1399AA02 |
| Leadtime 2-3 weeks | LWB42-UM8-VC1 | LINE FILTER 250VAC 2A CHASS MNT | F1399 | Active | Single Phase | Two Stage | - | 250V | - | - | 2A | 50 60Hz | General Purpose | CE, CSA, TUV, UR | - | Chassis Mount | Quick Connect | - | ||||||||||||||
RSEN-2030L![]() | RSEN-2030L |
| Leadtime 2-3 weeks | TZD-K9-HY8 | LINE FILTER 250VDC VAC 30A CHASS | RSEN | Active | Single Phase | Single Stage | 250V | 250V | - | - | 30A | - | General Purpose | CSA, EN, UL | -25°C ~ 85°C | Chassis Mount | Terminal Block | - | ||||||||||||||
FN2200-50-34![]() | FN2200-50-34 |
| Leadtime 2-3 weeks | S405-FG-TB4 | LINE FILTER 1.2KVDC 50A CHASS | FN 2200 | Active | DC | Single Stage | 1200V 1.2kV | - | - | - | 50A | - | Photovoltaic Inverter | cURus, ENEC | -40°C ~ 100°C | Chassis Mount | Terminal Post | - | ||||||||||||||
FN2070-1-06 | FN2070-1-06 |
| Leadtime 2-3 weeks | WPCA-OJH-4Q | LINE FILTER 110 250VAC 1A CHAS | FN 2070 | Active | Single Phase | Two Stage | - | 110V, 250V | - | - | 1A | DC ~ 400Hz | General Purpose | CSA, ENEC, UR | -25°C ~ 100°C | Chassis Mount | Quick Connect | 22mH | ||||||||||||||
10ER11![]() | 10ER11 | 7 | 7BKDV-MIV-ELV | LINE FILTER 250VAC 10A CHASS MNT | ER, Curtis Industries PREO | Obsolete | Single Phase | Two Stage | - | 250V | - | - | 10A | 50 60Hz | General Purpose | CSA, UR, VDE | - | Chassis Mount | Quick Connect | - | |||||||||||||||
7-1609097-9 | 7-1609097-9 |
| Leadtime 2-3 weeks | ODYC0-GJ0F-COC | LINE FILTER 250VAC 16A CHASS MNT | HQ | Active | Single Phase | Two Stage | - | 250V | - | - | 16A | 50 60Hz | General Purpose | CSA, UR, VDE | -10°C ~ 40°C | Chassis Mount | Quick Connect | 8.3mH | ||||||||||||||
FN3311-1000-99-C16-R55![]() | FN3311-1000-99-C16-R55 |
| 8 | 8JW9-FBV-X0B | LINE FILTER 520 300VAC 1KA CHASS | FN 3311 | Active | Three Phase Delta | Single Stage | - | 520V, 300V | 300V | 520V | 1kA | 60Hz | General Purpose | CE, cURus, ENEC | -40°C ~ 100°C | Chassis Mount | Terminal Post | - | ||||||||||||||
05DBAW5 | 05DBAW5 |
| Leadtime 2-3 weeks | V5AFY-49-NHY | LINE FILTER 115 250VAC 5A CHAS | DB | Active | Single Phase | Single Stage | - | 115V, 250V | - | - | 5A | 50 60Hz | General Purpose | CSA, UR, VDE | -25°C ~ 100°C | Chassis Mount | Wire Leads | 2.9mH | ||||||||||||||
B84143B36R112![]() | B84143B36R112 | 49 | 49AM-MVE-5N | LINE FILTER 520 300VAC 36A CHASS | B84143B | Obsolete | Three Phase Delta | Two Stage | - | 520V, 300V | - | - | 36A | 50 60Hz | General Purpose | - | -25°C ~ 100°C | Chassis Mount | Terminal Block, Wire Leads | - | |||||||||||||||
FN610-30-03 | FN610-30-03 |
| Leadtime 2-3 weeks | N0IK0-WP-B24 | LINE FILTER 250VAC 30A CHASS MNT | FN 610 | Last Time Buy | Single Phase | Single Stage | - | 250V | - | - | 30A | DC ~ 400Hz | General Purpose | CSA, ENEC, UR | -25°C ~ 100°C | Chassis Mount | Terminal Block | 610µH |