Supplier Part Number | Manufacturer Part Number | Price | Stock | Manufacturer | Description | Series | Part Status | Filter Type | Configuration | Voltage - Rated DC | Voltage - Rated AC | Voltage - Rated AC ... | Voltage - Rated AC ... | Current | Frequency - Operating ... | Applications | Approvals | Operating Temperature ... | Mounting Type | Termination Style | Inductance | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
B84115EB60 | B84115EB60 |
| Leadtime 2-3 weeks | UU-CKIV-986 | LINE FILTER 250VDC VAC 6A CHASS | B84115E | Active | Single Phase | Two Stage | 250V | 250V | - | - | 6A | 50 60Hz | General Purpose | CSA, ENEC, UR | -25°C ~ 85°C | Chassis Mount | Quick Connect | L1 - 100µH, L2 - 4.7mH | ||||||||||||||
FN405-6-02 | FN405-6-02 |
| 4 | 4D-FKHE-J7 | LINE FILTER 250VAC 6A TH | FN 405 | Active | Single Phase | Single Stage | - | 250V | - | - | 6A | DC ~ 400Hz | General Purpose | CSA, ENEC, UR | -25°C ~ 100°C | Through Hole | PC Pins | 800µH | ||||||||||||||
F1350AA03![]() | F1350AA03 |
| Leadtime 2-3 weeks | C8H-B0-S3 | LINE FILTER 250VAC 3A CHASS MNT | F1350 | Active | Single Phase | Two Stage | - | 250V | - | - | 3A | 50 60Hz | General Purpose | CE, CSA, TUV, UR | - | Chassis Mount | Quick Connect | - | ||||||||||||||
5500.2129![]() | 5500.2129 |
| Leadtime 2-3 weeks | F2R1B-OHQ-J9Q | LINE FILTER 125 250VAC 800MA TH | FPP-02 | Active | Single Phase | Single Stage | - | 125V, 250V | - | - | 800mA | 50 60Hz | General Purpose | cURus, ENEC, VDE | -25°C ~ 85°C | Through Hole | PC Pins | 20mH | ||||||||||||||
5500.2226 | 5500.2226 |
| 4 | 4SXGT-BA-C8M | LINE FILTER 43VDC 80VDC 20A CHAS | FMEB | Active | DC | Single Stage | 43V, 80V | - | - | - | 20A | - | General Purpose | cURus, ENEC, VDE | -25°C ~ 100°C | Chassis Mount | Quick Connect | 70µH | ||||||||||||||
RTEN-5020 | RTEN-5020 |
| 35 | 35-HX-5H6 | LINE FILTER 500VDC VAC 20A CHASS | RTEN | Active | Three Phase Delta | Single Stage | 500V | 500V | - | - | 20A | - | General Purpose | EN, UL | -25°C ~ 85°C | Chassis Mount | Terminal Block | - | ||||||||||||||
PS03 A0620 63![]() | PS03 A0620 63 |
| 2 | 2XXL-FT-0WN | LINE FILTER 250VAC 6A CHASS MNT | PS03 | Active | Single Phase | Single Stage | - | 250V | - | - | 6A | 50 ~ 400Hz | General Purpose | CSA, ENEC, UR, VDE | -25°C ~ 85°C | Chassis Mount | Quick Connect | 700µH | ||||||||||||||
FN660B-10-06 | FN660B-10-06 |
| Leadtime 2-3 weeks | PMM-C2-UG | LINE FILTER 250VAC 10A CHASS MNT | FN 660 | Last Time Buy | Single Phase | Two Stage | - | 250V | - | - | 10A | DC ~ 400Hz | General Purpose | CSA, ENEC, UR | -25°C ~ 100°C | Chassis Mount | Quick Connect | 450µH | ||||||||||||||
V51Z-3C-3OC![]() | V51Z-3C-3OC | Leadtime 2-3 weeks | U33-7GVE-PNJ | LINE FILTER 250VAC 6A CHASS MNT | ER, Curtis Industries PREO | Obsolete | Single Phase | Two Stage | - | 250V | - | - | 6A | 50 60Hz | General Purpose | CSA, UR, VDE | - | Chassis Mount | Quick Connect | - | |||||||||||||||
20EK1![]() | 20EK1 |
| Leadtime 2-3 weeks | IE-7G0-AI8 | LINE FILTER 250VAC 20A CHASS MNT | K | Active | Single Phase | Single Stage | - | 250V | - | - | 20A | 50 60Hz | General Purpose | CSA, UR, VDE | -10°C ~ 40°C | Chassis Mount | Quick Connect | 440µH | ||||||||||||||
4RF-WQ67-PK | 4RF-WQ67-PK |
| Leadtime 2-3 weeks | PN-49-PF | LINE FILTER 520VAC CHASSIS MOUNT | TYT | Active | Three Phase Wye | Single Stage | - | 520V | - | - | - | 50 60Hz | General Purpose | UR | - | Chassis Mount | Terminal Block | 1mH | ||||||||||||||
5500.2063![]() | 5500.2063 |
| Leadtime 2-3 weeks | 0M2CV-24DZ-DU | LINE FILTER 125 250VAC 10A CHASS | FSW | Active | Single Phase | Single Stage | - | 125V, 250V | - | - | 10A | 50 60Hz | Inverters, Power Drive Systems | cURus, ENEC, VDE | -25°C ~ 100°C | Chassis Mount | Quick Connect | 400µH | ||||||||||||||
B5-JN-MC![]() | B5-JN-MC |
| Leadtime 2-3 weeks | DKAM7-SZJ-2OD | LINE FILTER 250VAC 6A CHASS MNT | FN 2060 | Active | Single Phase | Two Stage | - | 250V | - | - | 6A | DC ~ 400Hz | Safety | CE, CSA, ENEC, UR | -25°C ~ 100°C | Chassis Mount | Quick Connect | 970µH | ||||||||||||||
EH-TMC-W0![]() | EH-TMC-W0 |
| Leadtime 2-3 weeks | NX-1U-CT | LINE FILTER 250VAC 6A CHASS MNT | SK | Active | Single Phase | Single Stage | - | 250V | - | - | 6A | 50 60Hz | General Purpose | CSA, UR, VDE | -10°C ~ 40°C | Chassis Mount | Wire Leads | 8.73mH | ||||||||||||||
F1299BB06 | F1299BB06 |
| 26 | 26OSK-83-NP | LINE FILTER 250VAC 6A CHASS MNT | F1299 | Active | Single Phase | Single Stage | - | 250V | - | - | 6A | 50 60Hz | General Purpose | CSA, UR, VDE | - | Chassis Mount | Wire Leads | - | ||||||||||||||
FN2090A-10-06![]() | FN2090A-10-06 |
| Leadtime 2-3 weeks | VBYT2-H9LC-TW | LINE FILTER 110 250VAC 10A CHASS | FN 2090 | Active | Single Phase | Two Stage | - | 110V, 250V | - | - | 10A | DC ~ 400Hz | Safety | CE, CSA, ENEC, UR | -20°C ~ 100°C | Chassis Mount | Quick Connect | 8mH | ||||||||||||||
FN258L-55-34![]() | FN258L-55-34 |
| Leadtime 2-3 weeks | FKFI-GNYZ-WC | LINE FILTER 55A CHASSIS MOUNT | FN 258 | Active | Three Phase Delta | Two Stage | - | - | 277V | 480V | 55A | DC ~ 60Hz | Inverters, Power Drive Systems | CSA, ENEC, UR | -25°C ~ 100°C | Chassis Mount | Terminal Block | - | ||||||||||||||
COWS2 FIT 4W4![]() | COWS2 FIT 4W4 | Leadtime 2 3 weeks | PSO7T-X9JQ-9S | LINE FILTER 250VAC 3A CHASS MNT | 62 AC | 0 | Single Phase | Single Stage | 250V | 3A | 50 60Hz | General Purpose | CSA, TUV, UR | 25°C ~ 85°C | Chassis Mount | Quick Connect | 2.4mH | ||||||||||||||||||
3EP3![]() | 3EP3 |
| Leadtime 2-3 weeks | O3E25-JKYD-YZ2 | LINE FILTER 250VAC 3A CHASS MNT | EP | Active | Single Phase | Two Stage | - | 250V | - | - | 3A | 50 60Hz | General Purpose | CSA, UR, VDE | -10°C ~ 40°C | Chassis Mount | Wire Leads | - | ||||||||||||||
XU9BV-33NT-G0![]() | XU9BV-33NT-G0 |
| 28 | 28Q-OTZ-2I7 | LINE FILTER 250VDC VAC 30A DIN | RSAN | Active | Single Phase | Single Stage | 250V | 250V | - | - | 30A | - | General Purpose | CSA, EN, UL | -25°C ~ 85°C | DIN Rail | Terminal Block | - | ||||||||||||||
B84299K53![]() | B84299K53 | Leadtime 2-3 weeks | YU5-LB-QRQ | LINE FILTER 440 250VAC 6A CHAS | B84299K | Obsolete | Three Phase Wye | Single Stage | - | 440V, 250V | - | - | 6A | 50 60Hz | General Purpose | VDE | -25°C ~ 85°C | Chassis Mount | Terminal Block | - | |||||||||||||||
G6-LHQ-Q1X | G6-LHQ-Q1X |
| Leadtime 2-3 weeks | IH-6VLD-KH | LINE FILTER 500VDC VAC 30A CHASS | RTAN | Active | Three Phase Delta | Single Stage | 500V | 500V | - | - | 30A | - | General Purpose | EN, UL | -25°C ~ 85°C | Chassis Mount | Terminal Block | - | ||||||||||||||
30BCF6R | 30BCF6R |
| 6 | 6GSQ0-0DH-L1 | LINE FILTER 30A CHASSIS MOUNT | BCFXR | Active | Three Phase Delta | Two Stage | - | - | 277V | 480V | 30A | 50 60Hz | General Purpose | CSA, UR, VDE | -10°C ~ 50°C | Chassis Mount | Threaded Post M5 | 1.6mH | ||||||||||||||
6EDK3![]() | 6EDK3 |
| Leadtime 2-3 weeks | U87-5DEC-2R7 | LINE FILTER 250VAC 6A CHASS MNT | DK | Active | Single Phase | Single Stage | - | 250V | - | - | 6A | 50 60Hz | General Purpose | CSA, UR, VDE | -10°C ~ 40°C | Chassis Mount | Wire Leads | 516µH | ||||||||||||||
BG7CN-HMJ7-AX | BG7CN-HMJ7-AX |
| Leadtime 2-3 weeks | OI41T-J6-HIM | LINE FILTER 115 250VAC 6A CHAS | 849 | Active | Single Phase | Two Stage | - | 115V, 250V | - | - | 6A | 50 60Hz | General Purpose | CSA, UR, VDE | -25°C ~ 85°C | Chassis Mount | Quick Connect | L1 - 1.7mH, L2 - 70µH |