Supplier Part Number | Manufacturer Part Number | Price | Stock | Manufacturer | Description | Series | Part Status | Filter Type | Configuration | Voltage - Rated DC | Voltage - Rated AC | Voltage - Rated AC ... | Voltage - Rated AC ... | Current | Frequency - Operating ... | Applications | Approvals | Operating Temperature ... | Mounting Type | Termination Style | Inductance | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
RSEN-2060![]() | RSEN-2060 |
| Leadtime 2-3 weeks | WFGAT-ZX-P1 | LINE FILTER 250VDC VAC 60A CHASS | RSEN | Active | Single Phase | Single Stage | 250V | 250V | - | - | 60A | - | General Purpose | CSA, EN, UL | -25°C ~ 85°C | Chassis Mount | Terminal Block | - | ||||||||||||||
BRHE L6 L6![]() | BRHE L6 L6 |
| Leadtime 2 3 weeks | ZVDD-DQY6-8L | LINE FILTER 115 250VAC 3A CHAS | 870 | Active | Single Phase | Two Stage | 115V, 250V | 3A | 50 60Hz | General Purpose | CSA, UR, VDE | 25°C ~ 85°C | Chassis Mount | Quick Connect | 10mH | |||||||||||||||||
F3600T008![]() | F3600T008 |
| Leadtime 2-3 weeks | QO5-P3KM-AU7 | LINE FILTER 600VAC 8A CHASS MNT | F3600 | Active | Three Phase Wye | Two Stage | - | 600V | - | - | 8A | 50 60Hz | General Purpose | UR | - | Chassis Mount | Terminal Block | - | ||||||||||||||
GJVQ-AY-4NC | GJVQ-AY-4NC |
| 2 | 2SQ-GF-TJE | LINE FILTER 250VAC 20A CHASS MNT | FN 612 | Last Time Buy | Single Phase | Single Stage | - | 250V | - | - | 20A | DC ~ 400Hz | General Purpose | CSA, ENEC, UR | -25°C ~ 100°C | Chassis Mount | Threaded Post 8-32 | 480µH | ||||||||||||||
RTEN-5006 | RTEN-5006 |
| Leadtime 2-3 weeks | WIP9-A6O-D3Z | LINE FILTER 500VDC VAC 6A CHASS | RTEN | Active | Three Phase Delta | Single Stage | 500V | 500V | - | - | 6A | - | General Purpose | EN, UL | -25°C ~ 85°C | Chassis Mount | Terminal Block | - | ||||||||||||||
FN2010-20-06 | FN2010-20-06 |
| Leadtime 2-3 weeks | GD4O-8AQ-1Y | LINE FILTER 250VAC 20A CHASS MNT | FN 2010 | Active | Single Phase | Single Stage | - | 250V | - | - | 20A | DC ~ 400Hz | General Purpose | CSA, ENEC, UR | -25°C ~ 100°C | Chassis Mount | Quick Connect | 600µH | ||||||||||||||
6609064-1![]() | 6609064-1 |
| Leadtime 2-3 weeks | D7-ZS-8O | LINE FILTER 250VAC 1A TH | EOP | Active | Single Phase | Single Stage | - | 250V | - | - | 1A | 50 60Hz | General Purpose | CSA, UR, VDE | -10°C ~ 40°C | Through Hole | PC Pins | - | ||||||||||||||
20VS6 | 20VS6 |
| Leadtime 2-3 weeks | IW-2C3-W4I | LINE FILTER 120 250VAC 20A CHASS | S | Active | Single Phase | Two Stage | - | 120V, 250V | - | - | 20A | 50 60Hz | General Purpose | CSA, UR, VDE | -10°C ~ 40°C | Chassis Mount | Threaded Post 8-32 | 960µH | ||||||||||||||
5500.2651.07![]() | 5500.2651.07 |
| 9 | 9PE-74-7ZP | LINE FILTER 125 250VAC 3A CHAS | FMAB NEO | Active | Single Phase | Single Stage | - | 125V, 250V | - | - | 3A | 50 60Hz | Medical | cURus, ENEC, VDE | -40°C ~ 100°C | Chassis Mount | Quick Connect | - | ||||||||||||||
FMER-G62V-Q057![]() | FMER-G62V-Q057 |
| 1 | 1YBA-RLM-9V | LINE FILTER 1.2KVDC 800A CHASS | FMER SOL | Active | DC | Single Stage | 1200V 1.2kV | - | - | - | 800A | - | Photovoltaic Inverter | cURus | -40°C ~ 100°C | Chassis Mount | Terminal Post | - | ||||||||||||||
03DCCG5B | 03DCCG5B |
| 2 | 2J-CJ-IJ | LINE FILTER 115 250VAC 3A CHAS | DC | Active | Single Phase | Two Stage | - | 115V, 250V | - | - | 3A | 50 60Hz | General Purpose | CSA, UR, VDE | - | Chassis Mount | Quick Connect | - | ||||||||||||||
B84266A21E13![]() | B84266A21E13 | Leadtime 2-3 weeks | N9Z1-3ZGO-1V | LINE FILTER 4A 250 440V | B84266 | Obsolete | - | - | - | - | - | - | 4A | - | General Purpose | - | - | - | - | - | |||||||||||||||
RSHN-2016 | RSHN-2016 |
| Leadtime 2-3 weeks | Z5-FRA-FAZ | LINE FILTER 250VDC VAC 16A CHASS | RSHN | Active | Single Phase | Two Stage | 250V | 250V | - | - | 16A | - | General Purpose | CSA, EN, UL | -25°C ~ 85°C | Chassis Mount | Terminal Block | - | ||||||||||||||
J9V-ML-9N![]() | J9V-ML-9N |
| Leadtime 2 3 weeks | EJ7P-N3-10 | LINE FILTER 4A CHASSIS MOUNT | FN 530 | Active | Three Phase Delta | Three Stage | 288V | 500V | 4A | General Purpose | 25°C ~ 100°C | Chassis Mount | Terminal Block, Wire Leads | |||||||||||||||||||
X2PY AT3 1H![]() | X2PY AT3 1H |
| Leadtime 2 3 weeks | 0O1A6-0EC-4ZM | LINE FILTER 250VAC 6A CHASS MNT | SK | Active | Single Phase | Single Stage | 250V | 6A | 50 60Hz | General Purpose | CSA, UR, VDE | 10°C ~ 40°C | Chassis Mount | Wire Leads | 8.73mH | |||||||||||||||||
851-05 005 | 851-05 005 |
| Leadtime 2-3 weeks | D0C-VZ-BFN | LINE FILTER 115 250VAC 5A CHAS | 851 | Active | Single Phase | Single Stage | - | 115V, 250V | - | - | 5A | 50 60Hz | General Purpose | CSA, UR, VDE | -25°C ~ 85°C | Chassis Mount | Quick Connect | 2.9mH | ||||||||||||||
IX0-1APD-F3![]() | IX0-1APD-F3 |
| 91 | 91CPM-JF-JAI | LINE FILTER 250A CHASSIS MOUNT | FN 3270 | Active | Three Phase Delta | Three Stage | - | - | 300V | 520V | 250A | DC ~ 60Hz | Inverters, Power Drive Systems | CSA, ENEC, UR | -25°C ~ 100°C | Chassis Mount | Terminal Post | - | ||||||||||||||
FN351H-36-33 | FN351H-36-33 |
| Leadtime 2-3 weeks | MMNFG-GU29-GB | LINE FILTER 36A CHASSIS MOUNT | FN 351 | Active | Three Phase Delta | Single Stage | - | - | 300V | 520V | 36A | DC ~ 60Hz | Inverters, Power Drive Systems | CSA, ENEC, UR | -25°C ~ 100°C | Chassis Mount | Terminal Block | - | ||||||||||||||
NI-AVH1-LN0 | NI-AVH1-LN0 |
| Leadtime 2-3 weeks | MNU-W1VL-3QV | LINE FILTER 250VAC 6.5A CHASS | FN 680 | Last Time Buy | Single Phase | Two Stage | - | 250V | - | - | 6.5A | DC ~ 400Hz | General Purpose | CSA, UR, VDE | - | Chassis Mount | Quick Connect | 4.1mH | ||||||||||||||
5500.2081![]() | 5500.2081 |
| 2147483647 | 52E9R-F4-SOE | LINE FILTER 125 250VAC 10A CHASS | FMLB-41 | Active | Single Phase | Single Stage | - | 125V, 250V | - | - | 10A | 50 60Hz | Medical | cURus, ENEC, VDE | -25°C ~ 100°C | Chassis Mount | Quick Connect | 300µH | ||||||||||||||
5500.2273![]() | 5500.2273 |
| 63 | 63O-86YQ-QUS | LINE FILTER 1A | - | Active | - | - | - | - | - | - | 1A | - | General Purpose | - | - | - | - | - | ||||||||||||||
B84144A66R120 | B84144A66R120 |
| Leadtime 2-3 weeks | S7CR-KGN-0E7 | LINE FILTER 520 300VAC 66A CHASS | B84144 | Active | Three Phase Wye | Single Stage | - | 520V, 300V | - | - | 66A | 50 60Hz | General Purpose | cUR, ENEC, UR | -25°C ~ 100°C | Chassis Mount | Terminal Block | - | ||||||||||||||
FN356-36-33 | FN356-36-33 |
| 3 | 3JQ-4W3A-K5 | LINE FILTER 36A CHASSIS MOUNT | FN 356 | Active | Three Phase Wye | Single Stage | - | - | 250V | 440V | 36A | DC ~ 60Hz | General Purpose | CSA, ENEC, UR | -25°C ~ 100°C | Chassis Mount | Terminal Block | - | ||||||||||||||
FN3270H-100-35 | FN3270H-100-35 |
| Leadtime 2-3 weeks | DSQ-ZR-FR5 | LINE FILTER 100A CHASSIS MOUNT | FN 3270 | Active | Three Phase Delta | Three Stage | - | - | 300V | 520V | 100A | DC ~ 60Hz | Inverters, Power Drive Systems | CSA, ENEC, UR | -25°C ~ 100°C | Chassis Mount | Terminal Block | - | ||||||||||||||
FN2060B-3-06 | FN2060B-3-06 |
| Leadtime 2-3 weeks | HTH-3M-78P | LINE FILTER 250VAC 3A CHASS MNT | FN 2060 | Active | Single Phase | Two Stage | - | 250V | - | - | 3A | DC ~ 400Hz | General Purpose | CE, CSA, ENEC, UR | -25°C ~ 100°C | Chassis Mount | Quick Connect | 2.5mH |