Supplier Part Number | Manufacturer Part Number | Price | Stock | Manufacturer | Description | Series | Part Status | Filter Type | Configuration | Voltage - Rated DC | Voltage - Rated AC | Voltage - Rated AC ... | Voltage - Rated AC ... | Current | Frequency - Operating ... | Applications | Approvals | Operating Temperature ... | Mounting Type | Termination Style | Inductance | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
F3480T060![]() | F3480T060 |
| Leadtime 2-3 weeks | W2P-HN91-HOD | LINE FILTER 480VAC 60A CHASS MNT | F3480 | Active | Three Phase Delta | Two Stage | - | 480V | - | - | 60A | 50 60Hz | General Purpose | CE, UR | - | Chassis Mount | Terminal Block | - | ||||||||||||||
RSAL-2001A | RSAL-2001A |
| Leadtime 2-3 weeks | STBP-PL-4DD | LINE FILTER 250VDC VAC 1A CHASS | RSAL | Active | Single Phase | Single Stage | 250V | 250V | - | - | 1A | - | General Purpose | CSA, EN, UL | -25°C ~ 85°C | Chassis Mount | Quick Connect | - | ||||||||||||||
FN258P-250-07![]() | FN258P-250-07 |
| 49 | 49NM-OH-K7 | LINE FILTER 250A CHASSIS MOUNT | FN 258 | Active | Three Phase Delta | Two Stage | - | - | 277V | 480V | 250A | DC ~ 60Hz | Inverters, Power Drive Systems | CSA, ENEC, UR | -25°C ~ 100°C | Chassis Mount | Terminal Block | - | ||||||||||||||
74-EQ-HZ | 74-EQ-HZ |
| Leadtime 2-3 weeks | JDRO0-NCX-YE | LINE FILTER 250VAC 3A CHASS MNT | Q | Active | Single Phase | Single Stage | - | 250V | - | - | 3A | 50 60Hz | General Purpose | CSA, UR, VDE | -10°C ~ 40°C | Chassis Mount | IEC 320-C14, Wire Leads | - | ||||||||||||||
Z5XA8-GC-90![]() | Z5XA8-GC-90 | Leadtime 2-3 weeks | VC-P49M-WBD | 3-PHASE EMC FILTER, CHASSIS MOUN | * | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | |||||||||||||||
B84112G0000B080 | B84112G0000B080 |
| 4 | 4DSLH-6T-JW | LINE FILTER 250VDC VAC 8A CHASS | B84112 | Active | Single Phase | Single Stage | 250V | 250V | - | - | 8A | 50 60Hz | General Purpose | cUR, ENEC, UR | -25°C ~ 100°C | Chassis Mount | Terminal Post | 2.5mH | ||||||||||||||
02DRCW5![]() | 02DRCW5 |
| Leadtime 2-3 weeks | QCXNO-N19Z-5VR | LINE FILTER 115 250VAC 2A CHAS | DR | Active | Single Phase | Two Stage | - | 115V, 250V | - | - | 2A | 50 60Hz | General Purpose | CSA, UR, VDE | -25°C ~ 100°C | Chassis Mount | Wire Leads | 2.4mH | ||||||||||||||
LLGV UV8E RI | LLGV UV8E RI |
| Leadtime 2 3 weeks | H4CJB-D4-BGV | LINE FILTER 250VDC VAC 36A CHASS | B84112G | Active | Single Phase | Single Stage | 250V | 250V | 36A | 50 60Hz | General Purpose | cUR, ENEC, UR | 25°C ~ 100°C | Chassis Mount | Threaded Post M5 | 800µH | ||||||||||||||||
28DCV-D7EH-8T![]() | 28DCV-D7EH-8T |
| Leadtime 2-3 weeks | BS1BJ-UWV-U9M | LINE FILTER 16A CHASSIS MOUNT | BCFXR | Active | Three Phase Delta | Two Stage | - | - | 277V | 480V | 16A | 50 60Hz | General Purpose | CSA, UR, VDE | -10°C ~ 50°C | Chassis Mount | Terminal Block | 2.01mH | ||||||||||||||
5500.2654.04![]() | 5500.2654.04 |
| 38 | 38OU-VYCZ-AH4 | LINE FILTER 125 250VAC 12A CHASS | FMAB NEO | Active | Single Phase | Single Stage | - | 125V, 250V | - | - | 12A | 50 60Hz | Medical | cURus, ENEC, VDE | -40°C ~ 100°C | Chassis Mount | Quick Connect | - | ||||||||||||||
FMBC-0938-5010L![]() | FMBC-0938-5010L |
| Leadtime 2-3 weeks | IDI-XC-Y0H | LINE FILTER 480VAC 50A CHASS MNT | FMBC | Active | Three Phase Delta | Two Stage | - | 480V | - | - | 50A | 50 60Hz | General Purpose | cURus, ENEC, VDE | -25°C ~ 100°C | Chassis Mount | Terminal Block | 1mH | ||||||||||||||
10LX-L8W-UEJ![]() | 10LX-L8W-UEJ |
| Leadtime 2-3 weeks | KY-KLU-51R | LINE FILTER 80VDC 75A CHASS MNT | FD | Active | DC | Single Stage | 80V | - | - | - | 75A | - | General Purpose | cUR, TUV, UR | - | Chassis Mount | Threaded Post 8-32 | - | ||||||||||||||
GRLLM-3YFY-TYT![]() | GRLLM-3YFY-TYT |
| Leadtime 2-3 weeks | L2WTJ-P6RK-5K | LINE FILTER 250VAC 12A CHASS MNT | FN 2020 | Active | Single Phase | Single Stage | - | 250V | - | - | 12A | DC ~ 400Hz | General Purpose | CSA, ENEC, UR | -25°C ~ 100°C | Chassis Mount | Quick Connect | 700µH | ||||||||||||||
ZD6-C3-ESJ![]() | ZD6-C3-ESJ | Leadtime 2-3 weeks | C5I6-9I-7KK | 3-PHASE EMC FILTER, CHASSIS MOUN | * | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | |||||||||||||||
B1VYR TBUV 3C1 | B1VYR TBUV 3C1 |
| Leadtime 2 3 weeks | LYU3C-VG-E1 | LINE FILTER 250VAC 4A TH | X | Active | Single Phase | Single Stage | 250V | 4A | 50 60Hz | General Purpose | CSA, UR, VDE | 10°C ~ 40°C | Through Hole | PC Pins | 2.2mH | |||||||||||||||||
1VR1 | 1VR1 |
| Leadtime 2-3 weeks | KY3-N2H3-IW | LINE FILTER 250VAC 1A CHASS MNT | R | Active | Single Phase | Two Stage | - | 250V | - | - | 1A | 50 60Hz | General Purpose | CSA, UR, VDE | -10°C ~ 40°C | Chassis Mount | Quick Connect | 3.72mH | ||||||||||||||
RSHN-2003 | RSHN-2003 |
| Leadtime 2-3 weeks | CI-AY4-SXP | LINE FILTER 250VDC VAC 3A CHASS | RSHN | Active | Single Phase | Two Stage | 250V | 250V | - | - | 3A | - | General Purpose | CSA, EN, UL | -25°C ~ 85°C | Chassis Mount | Terminal Block | - | ||||||||||||||
FN402-1.6-02 | FN402-1.6-02 |
| Leadtime 2-3 weeks | F62T-32XH-7T | LINE FILTER 250VAC 1.6A TH | FN 402 | Active | Single Phase | Single Stage | - | 250V | - | - | 1.6A | DC ~ 400Hz | General Purpose | CSA, ENEC, UR | -25°C ~ 100°C | Through Hole | PC Pins | 6mH | ||||||||||||||
FN2010-6-06 | FN2010-6-06 |
| Leadtime 2-3 weeks | FIKUU-JM9P-PZ | LINE FILTER 250VAC 6A CHASS MNT | FN 2010 | Active | Single Phase | Single Stage | - | 250V | - | - | 6A | DC ~ 400Hz | General Purpose | CSA, ENEC, UR | -25°C ~ 100°C | Chassis Mount | Quick Connect | 1mH | ||||||||||||||
RSAN-2030LD![]() | RSAN-2030LD |
| Leadtime 2-3 weeks | 289E-9B-7PG | LINE FILTER 250VDC VAC 30A DIN | RSAN | Active | Single Phase | Single Stage | 250V | 250V | - | - | 30A | - | General Purpose | CSA, EN, UL | -25°C ~ 85°C | DIN Rail | Terminal Block | - | ||||||||||||||
B86306A0304S000![]() | B86306A0304S000 |
| 7 | 7QG-7Q-HE | LINE FILTER 520VAC 304A CHASS | B86306 | Active | Three Phase Delta | Single Stage | - | 520V | - | - | 304A | 50 60Hz | General Purpose | - | -25°C ~ 100°C | Chassis Mount | Terminal Block, Wire Leads | 160µH | ||||||||||||||
1000APH12P | 1000APH12P |
| Leadtime 2-3 weeks | DXDQR-3MEB-PS | LINE FILTER 690VAC 1KA CHASS MNT | APH | Active | Three Phase Delta | Three Stage | - | 690V | - | - | 1kA | 50 60Hz | General Purpose | - | -10°C ~ 50°C | Chassis Mount | Quick Connect | - | ||||||||||||||
1-1609034-3![]() | 1-1609034-3 |
| Leadtime 2-3 weeks | WBO-JTO-51 | LINE FILTER 250VDC VAC 10A CHASS | SB | Active | Single Phase | Single Stage | 250V | 250V | - | - | 10A | 50 60Hz | General Purpose | CSA, UR, VDE | -10°C ~ 40°C | Chassis Mount | Quick Connect | 1.1mH | ||||||||||||||
MI-K2Q-AMM | MI-K2Q-AMM |
| Leadtime 2-3 weeks | NAG-GY-4F | LINE FILTER 16A CHASSIS MOUNT | FCD | Active | Three Phase Delta | Two Stage | - | - | 277V | 480V | 16A | 50 60Hz | Regenerative Motor Drive | UR | -10°C ~ 40°C | Chassis Mount | Terminal Block | - | ||||||||||||||
FN258L-180-07![]() | FN258L-180-07 |
| Leadtime 2-3 weeks | J0W-DUC-UO | LINE FILTER 180A CHASSIS MOUNT | FN 258 | Active | Three Phase Delta | Two Stage | - | - | 277V | 480V | 180A | DC ~ 60Hz | Inverters, Power Drive Systems | CSA, ENEC, UR | -25°C ~ 100°C | Chassis Mount | Terminal Block | - |