Supplier Part Number | Manufacturer Part Number | Price | Stock | Manufacturer | Description | Series | Part Status | Filter Type | Configuration | Voltage - Rated DC | Voltage - Rated AC | Voltage - Rated AC ... | Voltage - Rated AC ... | Current | Frequency - Operating ... | Applications | Approvals | Operating Temperature ... | Mounting Type | Termination Style | Inductance | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
FN5040-1200-99![]() | FN5040-1200-99 |
| Leadtime 2-3 weeks | DKOX-F0C-ES3 | LINE FILTER 1.2KA CHASSIS MOUNT | FN 5040 | Active | Three Phase Delta | Single Stage | - | - | - | - | 1.2kA | - | Regenerative Motor Drive | cURus | -25°C ~ 70°C | Chassis Mount | Terminal Block | 75µH | ||||||||||||||
6609064-1![]() | 6609064-1 |
| Leadtime 2-3 weeks | Y0Y-KSCY-WX | LINE FILTER 250VAC 1A TH | EOP | Active | Single Phase | Single Stage | - | 250V | - | - | 1A | 50 60Hz | General Purpose | CSA, UR, VDE | -10°C ~ 40°C | Through Hole | PC Pins | - | ||||||||||||||
50TDS6D | 50TDS6D |
| Leadtime 2-3 weeks | BV46-J52-XWH | LINE FILTER 440VAC 50A CHASS MNT | TD | Active | Three Phase Delta | Two Stage | - | 440V | - | - | 50A | 50 60Hz | General Purpose | - | - | Chassis Mount | Threaded Post M6 | L1 - 14µH, L2 - 600µH | ||||||||||||||
5500.2057 | 5500.2057 |
| Leadtime 2-3 weeks | JKZ-HM-KW | LINE FILTER 125 250VAC 16A CHASS | FSS | Active | Single Phase | Two Stage | - | 125V, 250V | - | - | 16A | 50 60Hz | General Purpose | cURus, ENEC, VDE | -25°C ~ 100°C | Chassis Mount | Quick Connect | - | ||||||||||||||
1VR1 | 1VR1 |
| Leadtime 2-3 weeks | SV-D2SN-BUE | LINE FILTER 250VAC 1A CHASS MNT | R | Active | Single Phase | Two Stage | - | 250V | - | - | 1A | 50 60Hz | General Purpose | CSA, UR, VDE | -10°C ~ 40°C | Chassis Mount | Quick Connect | 3.72mH | ||||||||||||||
0S-YEJ9-NO8![]() | 0S-YEJ9-NO8 | Leadtime 2-3 weeks | NU30M-YDTK-ZL | LINE FILTER 18A CHASSIS MOUNT | FN 5010 | Obsolete | Three Phase Delta | Single Stage | - | - | 230V | 400V | 18A | - | Inverters, Power Drive Systems | - | -25°C ~ 85°C | Chassis Mount | Terminal Block | 3.5mH | |||||||||||||||
OFH-N30-6ZA | OFH-N30-6ZA |
| 3 | 3A-J7F3-6MP | LINE FILTER 250VDC VAC 20A CHASS | RSAN | Active | Single Phase | Single Stage | 250V | 250V | - | - | 20A | - | General Purpose | CSA, EN, UL | -25°C ~ 85°C | Chassis Mount | Terminal Block | - | ||||||||||||||
FN332-1-05 | FN332-1-05 |
| Leadtime 2-3 weeks | M3-1T-AHK | LINE FILTER 250VAC 1A CHASS MNT | FN 332 | Active | Single Phase | Single Stage | - | 250V | - | - | 1A | DC ~ 400Hz | General Purpose | CSA, ENEC, UR | -25°C ~ 100°C | Chassis Mount | Terminal Post | 10mH | ||||||||||||||
FN520-8-29![]() | FN520-8-29 | Leadtime 2-3 weeks | K1R1-6M-OOQ | LINE FILTER 8A CHASSIS MOUNT | FN 520 | Obsolete | Three Phase Delta | Single Stage | - | - | 288V | 500V | 8A | - | Regenerative Motor Drive | - | -25°C ~ 100°C | Chassis Mount | Terminal Block | - | |||||||||||||||
1KXC6-3C1-2YF![]() | 1KXC6-3C1-2YF |
| Leadtime 2-3 weeks | NRV-PSG-HII | LINE FILTER 30A CHASSIS MOUNT | BCF | Active | Three Phase Delta | Two Stage | - | - | 277V | 480V | 30A | 50 60Hz | Inverters, Power Drive Systems | UR, VDE | -10°C ~ 50°C | Chassis Mount | Threaded Post M5 | - | ||||||||||||||
500TDSS84 | 500TDSS84 |
| Leadtime 2-3 weeks | MJ2Y-XC3-RO | LINE FILTER 480VAC 500A CHASS | TDS | Active | Three Phase Delta | Single Stage | - | 480V | - | - | 500A | 50 60Hz | General Purpose | - | - | Chassis Mount | Quick Connect | 3µH | ||||||||||||||
FN3100-200-40![]() | FN3100-200-40 |
| Leadtime 2-3 weeks | M8-I3-5D | LINE FILTER 200A CHASSIS MOUNT | FN 3100 | Active | Three Phase Delta | Single Stage | - | - | 300V | 520V | 200A | DC ~ 60Hz | Regenerative Motor Drive | CSA, SEMKO, UR | -25°C ~ 100°C | Chassis Mount | Terminal Block | - | ||||||||||||||
5500.2055![]() | 5500.2055 |
| Leadtime 2-3 weeks | FLW-4LXY-V7P | LINE FILTER 125 250VAC 6A CHAS | FSS | Active | Single Phase | Two Stage | - | 125V, 250V | - | - | 6A | 50 60Hz | General Purpose | cURus, ENEC, VDE | -25°C ~ 100°C | Chassis Mount | Quick Connect | - | ||||||||||||||
MAW120122![]() | MAW120122 | Leadtime 2-3 weeks | FLA6I-FB-VDP | LINE FILTER 250VDC VAC 1A CHASS | MAW | Obsolete | Single Phase | Single Stage | 250V | 250V | - | - | 1A | - | General Purpose | CSA, UL, VDE | -25°C ~ 85°C | Chassis Mount | Wire Leads | - | |||||||||||||||
5500.2651.04![]() | 5500.2651.04 |
| Leadtime 2-3 weeks | VB-8S7F-YW | LINE FILTER 125 250VAC 3A CHAS | FMAB NEO | Active | Single Phase | Single Stage | - | 125V, 250V | - | - | 3A | 50 60Hz | Medical | cURus, ENEC, VDE | -40°C ~ 100°C | Chassis Mount | Quick Connect | - | ||||||||||||||
FN2450B-16-61 | FN2450B-16-61 |
| Leadtime 2-3 weeks | ASOF3-K2VG-HO | LINE FILTER 250VAC 16A CHASS MNT | FN 2450 | Active | Single Phase | Single Stage | - | 250V | - | - | 16A | DC ~ 400Hz | General Purpose | CSA, ENEC, UR | -25°C ~ 100°C | Chassis Mount | Terminal Block | 1.84mH | ||||||||||||||
5500.2654.01![]() | 5500.2654.01 |
| Leadtime 2-3 weeks | H98-RGDG-GPW | LINE FILTER 125 250VAC 12A CHASS | FMAB NEO | Active | Single Phase | Single Stage | - | 125V, 250V | - | - | 12A | 50 60Hz | General Purpose | cURus, ENEC, VDE | -40°C ~ 100°C | Chassis Mount | Quick Connect | - | ||||||||||||||
EUJGA 1NER 592![]() | EUJGA 1NER 592 |
| Leadtime 2 3 weeks | Y1-GL9J-MX | LINE FILTER 250VAC 5A CHASS MNT | R | Active | Single Phase | Two Stage | 250V | 5A | 50 60Hz | General Purpose | CSA, UR, VDE | 10°C ~ 40°C | Chassis Mount | IEC 320 C14, Quick Connect | ||||||||||||||||||
5500.2644.07![]() | 5500.2644.07 |
| 308 | 308-LWT-07 | LINE FILTER 125 250VAC 12A CHASS | FMAB NEO | Active | Single Phase | Single Stage | - | 125V, 250V | - | - | 12A | 50 60Hz | Medical | cURus, ENEC, VDE | -40°C ~ 100°C | Chassis Mount | Quick Connect | - | ||||||||||||||
FN3268-42-33 | FN3268-42-33 |
| Leadtime 2-3 weeks | EZU-V8-9OO | LINE FILTER 42A CHASSIS MOUNT | FN 3268 | Active | Three Phase Delta | Single Stage | - | - | 300V | 520V | 42A | DC ~ 60Hz | General Purpose | CSA, ENEC, UR | -25°C ~ 100°C | Chassis Mount | Terminal Block | - | ||||||||||||||
FMAC-0A27-1613![]() | FMAC-0A27-1613 |
| Leadtime 2-3 weeks | EJDD-OTRH-C4R | LINE FILTER 550VAC 16A CHASS MNT | FMAC-Out | Active | Three Phase Delta | Single Stage | - | 550V | - | - | 16A | 50 60Hz | General Purpose | cURus, ENEC, VDE | -25°C ~ 100°C | Chassis Mount | Terminal Block | 200µH | ||||||||||||||
VOEDH-J7G-K4 | VOEDH-J7G-K4 |
| 8 | 8DG-1E-XBC | LINE FILTER 250VAC 20A CHASS MNT | FN 2020 | Active | Single Phase | Single Stage | - | 250V | - | - | 20A | DC ~ 400Hz | Safety | CSA, ENEC, UR | -25°C ~ 100°C | Chassis Mount | Quick Connect | 600µH | ||||||||||||||
30BCF6R | 30BCF6R |
| Leadtime 2-3 weeks | SRLL7-A8-XW | LINE FILTER 30A CHASSIS MOUNT | BCFXR | Active | Three Phase Delta | Two Stage | - | - | 277V | 480V | 30A | 50 60Hz | General Purpose | CSA, UR, VDE | -10°C ~ 50°C | Chassis Mount | Threaded Post M5 | 1.6mH | ||||||||||||||
30BCF6R | 30BCF6R |
| Leadtime 2-3 weeks | NYEXX-R48O-FBG | LINE FILTER 30A CHASSIS MOUNT | BCFXR | Active | Three Phase Delta | Two Stage | - | - | 277V | 480V | 30A | 50 60Hz | General Purpose | CSA, UR, VDE | -10°C ~ 50°C | Chassis Mount | Threaded Post M5 | 1.6mH | ||||||||||||||
FN2090B-4-06![]() | FN2090B-4-06 |
| Leadtime 2-3 weeks | FP2-MOW-G4 | LINE FILTER 110 250VAC 4A CHAS | FN 2090 | Active | Single Phase | Two Stage | - | 110V, 250V | - | - | 4A | DC ~ 400Hz | General Purpose | CE, CSA, ENEC, UR | -20°C ~ 100°C | Chassis Mount | Quick Connect | 14mH |