Supplier Part Number | Manufacturer Part Number | Price | Stock | Manufacturer | Description | Series | Part Status | Type | Specifications | Ratings | ||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
0QD16-2EC-WDG![]() | 0QD16-2EC-WDG | 5 | 5T2-4D-A0T | ADAPTER 400A AC CURRENT | - | Obsolete | Current Clamp, Probe Add On | Measures AC Current to 400A, Banana Interface | CAT II 600V, CAT III 300V | |||||||
FLK-A3001FC KIT![]() | FLK-A3001FC KIT |
| 4 | 4AXT-L02J-G76 | FC WIRELESS BASIC KIT W I3000 | Fluke Connect™ | Active | Current Clamp, Probe Add On | Measures AC Current 0.5A ~ 2500A | CAT III 1000V, CAT IV 600V | ||||||
NPLE P6 J9Z![]() | NPLE P6 J9Z | Leadtime 2 3 weeks | CB8-A08C-IQ | AC CURRENT FLEX 6000A 4 PACK | 430 | Obsolete | Current Clamp, Probe Add On | Measures AC Current to 6000A, BNC Interface | CAT III 1000V, CAT IV 600V | |||||||
PRM-4![]() | PRM-4 |
| Leadtime 2-3 weeks | F4YA-MLW-ON4 | PHASE SEQ&MOTOR ROTATION TESTER | - | Active | Phase Rotation Indicator | Detects the Rotary Field of Three-Phase Systems | CAT III 600V | ||||||
FLUKE-1625![]() | FLUKE-1625 | 6 | 6B-6KJ-QN | GROUND TESTER ADVANCED GEO EARTH | 1625 | Obsolete | Earth Ground Testers | Measures Resistance 0.001 ~ 300 kOhm | CAT II 300V | |||||||
MGP0-FI4-HUR![]() | MGP0-FI4-HUR | Leadtime 2-3 weeks | R6-O8X-Y3A | PROBE CURRENT 30A 50MHZ | AP | Obsolete | Current Probe | - | - | |||||||
FWSE H03S S84![]() | FWSE H03S S84 |
| Leadtime 2 3 weeks | CP-0UB-BHB | CURRENT CLAMP AC | Active | Current Clamp, Probe Add On | Measures AC Current to 1000A, BNC Interface | CAT III 600V | |||||||
14RTE-REO-JYO![]() | 14RTE-REO-JYO |
| 5 | 5Q441-Z0-76 | PHS SEQUENCE MTR ROTATN TESTER | - | Active | Phase Rotation Indicator | Detects the Rotary Field of Three-Phase Systems | CAT IV 600V | ||||||
FLUKE-374![]() | FLUKE-374 | 7 | 7MR-UI-2CW | 600A TRMS AC DC CLAMP | - | Obsolete | Current Clamp Meter | DMM Functions Include Voltage, Resistance, Capacitance and Current to 600A | CAT III 1000V, CAT IV 600V | |||||||
6EX-AG-8B![]() | 6EX-AG-8B |
| Leadtime 2-3 weeks | U8-Y6KB-5VF | 600A AC TRMS NAVIGATOR CLAMP | Navigator™ | Active | Current Clamp Meter | DMM Functions Include Voltage, Resistance, Capacitance, Temperature, Frequency and Current to 600A | CAT III 1000V, CAT IV 600V | ||||||
OD9MG-S70J-KEH![]() | OD9MG-S70J-KEH |
| Leadtime 2-3 weeks | N7UZ-RTCY-8W | DISPLAY DIG CLAMP-ON DMM RMS | ACD | Active | Current Clamp Meter | DMM Functions Include Voltage, Resistance, Capacitance, Temperature, Frequency and Current to 600A | CAT III 600V | ||||||
3310-PR-TF![]() | 3310-PR-TF | Leadtime 2-3 weeks | RKK-CA8-39 | 5000A FLUKE 1750 THIN FLEXI 61CM | - | Obsolete | Current Clamp, Probe Add On | Measures AC Current to 5000A, BNC Interface | CAT III 1000V, CAT IV 600V | |||||||
JK56I BT3 TZO![]() | JK56I BT3 TZO |
| Leadtime 2 3 weeks | UM7HV-XMBN-YN | MASTER CHECK 3.2 VOLTAGE TESTER | Active | Voltage Detector | Measures AC, DC Voltage 6 ~ 400VAC, 6 ~ 400VDC | ||||||||
I17XX-FLEX3000 4PK![]() | I17XX-FLEX3000 4PK |
| 8 | 8QRQO-R2GL-4BJ | FLUKE-17XX IFLEXI 3000A 24 IN 4 | Fluke Connect™ | Active | Current Clamp, Probe Add On | Measures AC Current to 3000A, BNC Interface | - | ||||||
BT-120![]() | BT-120 |
| 9 | 9QGR-PIN-8T | BREAKER FINDER | - | Active | Wire Tracer | Identifies Breaker Location for 90 ~ 120V Systems | CAT II 120V | ||||||
W3-CM-IX8![]() | W3-CM-IX8 |
| Leadtime 2 3 weeks | CJ-XNQK-I40 | ADVANCED WIRE TRACER, W HARDCASE | AT | Active | Wire Tracer | Identifies Breakers, Open Circuits and Pinouts in Various Cable Types | |||||||
LNX-P5T-VS![]() | LNX-P5T-VS |
| Leadtime 2 3 weeks | 0R0A-6W1X-IX7 | 1000A FLUKE 1750 THIN FLEXI 61CM | Active | Current Clamp, Probe Add On | Measures AC Current to 1000A, BNC Interface | CAT III 1000V, CAT IV 600V | |||||||
60K-RAB-C6L![]() | 60K-RAB-C6L | 5 | 5WN6-IG56-TI | CLAMPMETER | - | Obsolete | Current Clamp Meter | DMM Functions Include Voltage, Resistance, Frequency and Current to 1000A | CAT III 600V | |||||||
CM-1500-C![]() | CM-1500-C | Leadtime 2-3 weeks | BSXI-CI-CS | CLAMPMETER AC DC | CM | Obsolete | Current Clamp Meter | DMM Functions Include Voltage, Resistance, Frequency and Current to 1000A | CAT III 1000V, CAT IV 600V | |||||||
I1A 10A CLAMP PQ3![]() | I1A 10A CLAMP PQ3 |
| Leadtime 2-3 weeks | OC-F0-1XW | 3-PHASE 1A 10A MINI CURRENT CLAM | - | Active | Current Clamp, Probe Add On | Measures AC Current to 10A, BNC Interface | CAT III 600V | ||||||
T3U-OBO6-KHC![]() | T3U-OBO6-KHC |
| 107 | 107-532V-ACM | OSCILLOSCOPE CURRENT PROBE 300KH | CP, Elditest™, Cal Test | Active | Current Clamp Meter | Measures AC, DC Current to 100A, BNC Interface | CAT II 600V, CAT III 300V | ||||||
YUV-SW-ZJ![]() | YUV-SW-ZJ | Leadtime 2-3 weeks | LO9L-VB7-E1 | ADAPTER CURRENT FLEX | - | Obsolete | Current Clamp, Probe Add On | Measures AC Current to 3000A, Banana Interface | CAT III 1000V | |||||||
AMP-330![]() | AMP-330 |
| Leadtime 2-3 weeks | WAQS0-SPC-5QW | 1000A ACDC TRMS CLAMP MULTIMETER | 300 | Active | Current Clamp Meter | Measures AC, DC Current to 1000A, Banana Interface | CAT III 1000V, CAT IV 600V | ||||||
EIT-A805-MUG![]() | EIT-A805-MUG | Leadtime 2-3 weeks | NQTC-T7-0RR | PROBE CURRENT 30A 50MHZ | AP | Obsolete | Current Probe | - | - | |||||||
HQZ0-VQ1B-4BC | HQZ0-VQ1B-4BC |
| Leadtime 2-3 weeks | ZQZGV-FE7D-SQ1 | BREAKER TRACER 90-250VAC | Break rTrac r™ | Active | Wire Tracer | Identifies Breaker Location for 90 ~ 280V Systems | CAT II 280V |