Supplier Part Number | Manufacturer Part Number | Price | Stock | Manufacturer | Description | Series | Part Status | Type | Voltage - Primary | Voltage - Secondary | Power (Watts) | 1st Connector | 2nd Connector | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
OT5 OQ BGA![]() | OT5 OQ BGA |
| Leadtime 2 3 weeks | J6GI8-FX-VX | TRANSFORMR ISOL 115 TO 115V 15VA | 169 | Active | Isolated | 115V | 115V | 15VA | Wire Leads | Wire Leads | ||||||||||||||
G6G-73MI-4RP![]() | G6G-73MI-4RP |
| Leadtime 2-3 weeks | QW69L-WLE-97 | XFRMR AUTO 115 230V 250VA | OF | Active | Non-Isolated Autotransformer | 115V, 230V | 115V, 230V | 250VA | Wire Leads | Wire Leads | ||||||||||||||
WRHNO-U7-O64![]() | WRHNO-U7-O64 |
| 2 | 2PWPY-1KH-G8S | XFRMR NON-ISLTD AUTO 480V 277V | 4500 | Active | Non-Isolated Autotransformer | 480V | 277V | 230VA | Wire Leads | Wire Leads | ||||||||||||||
9A3 TN AD0![]() | 9A3 TN AD0 |
| Leadtime 2 3 weeks | FOZS-MRI-ZJ | TRANSFMR 115V TAPS 90 130V 250VA | 169 | Active | Isolated | 115V | 90V, 100V, 110V, 115V, 120V, 130V | 250VA | Wire Leads | Wire Leads | ||||||||||||||
CP5I0-F6YT-75 | CP5I0-F6YT-75 |
| 2 | 2IVQ-CI-CI | XFRMR 480 277V 375VA STEP-DOWN | - | Active | Non-Isolated Autotransformer | 347V, 480V | 200V, 277V | 270VA, 375VA | Wire Leads | Wire Leads | ||||||||||||||
T9E-L0-S14![]() | T9E-L0-S14 |
| 1 | 1O81N-7X-9IB | XFRMR AUTO 115 230V 120VA | OF | Active | Non-Isolated Autotransformer | 115V, 230V | 115V, 230V | 120VA | Wire Leads | Wire Leads | ||||||||||||||
TB R1L WTE![]() | TB R1L WTE | Leadtime 2 3 weeks | GRU1-M470-TN | TRANSFORMR ISOL 115 TO 95V 750VA | 179 | Obsolete | Isolated | 115V | 95V | 750VA | NEMA 5 15P | NEMA 5 15R 2 | |||||||||||||||
UYQ0Y-9SD4-T0![]() | UYQ0Y-9SD4-T0 |
| Leadtime 2-3 weeks | U7AM2-NDI-0O | TRANSFRMR ISOL 115 TO 115V 250VA | 169 | Active | Isolated | 115V | 115V | 250VA | Wire Leads | Wire Leads | ||||||||||||||
LZ46I-0L72-JBX![]() | LZ46I-0L72-JBX |
| Leadtime 2-3 weeks | N0-DM7-9Z | XFRMR AUTO 115 230V 300VA | OF | Active | Non-Isolated Autotransformer | 115V, 230V | 115V, 230V | 300VA | Wire Leads | Wire Leads | ||||||||||||||
1150![]() | 1150 |
| Leadtime 2-3 weeks | KV6I7-5K-R3 | XFRMR AUTO 230 115V 1500VA | EB | Active | Non-Isolated Autotransformer | 230V | 115V | 1500VA | NEMA 5-15P | NEMA 5-15R | ||||||||||||||
HV3X-ON-GCP![]() | HV3X-ON-GCP |
| Leadtime 2-3 weeks | TXL7-RV-2C | TRANSFORMER AUTO STEP UP PLG | 176 | Active | Non-Isolated Autotransformer | 115V | 230V | 120VA | NEMA 5-15P | NEMA 6-15R | ||||||||||||||
IGRV VN4O V6U![]() | IGRV VN4O V6U |
| 5 | 5MI-W8GP-JO | TRANSFORMR AUTO 115 230VAC 500VA | 170 | Active | Non Isolated Autotransformer | 115V, 230V | 115V, 230V | 500VA | Wire Leads | Wire Leads | ||||||||||||||
C5L-YP-ILL | C5L-YP-ILL |
| Leadtime 2-3 weeks | Y0GN-J8X-XM | MED GRADE ENC ISOLATION XFORMR | MD | Active | Isolated, Medical Grade | 120V | 120V | 2000VA | NEMA 5-15P | NEMA 5-15R 2 | ||||||||||||||
298F![]() | 298F | Leadtime 2-3 weeks | HS63-009Y-E7 | TRANSFMR ISOL 115 TO 230VCT 1KVA | 298 | Obsolete | Isolated | 115V | 230V | 1000VA | NEMA 5-15P | - | |||||||||||||||
W4-XL-RQE![]() | W4-XL-RQE |
| Leadtime 2 3 weeks | RPP-8Z-UA | TRANSFORMER ISOL | N | Active | Isolated | 115V | 115V | 100VA | Wire Leads | Wire Leads | ||||||||||||||
XON-S0MD-N88![]() | XON-S0MD-N88 |
| 69 | 69-J3R-A3K | XFRMR NON-ISLTD AUTO 480V 277V | 4500 | Active | Non-Isolated Autotransformer | 480V | 277V | 230VA | Wire Leads | Wire Leads | ||||||||||||||
UAV5A-33SY-CA![]() | UAV5A-33SY-CA |
| Leadtime 2-3 weeks | KNI-K65-AO | TRANSF AUTO 230-115V 1.5KVA USA | 175 | Active | Non-Isolated Autotransformer | 230V | 115V | 1500VA | NEMA 6-15P | NEMA 5-15R | ||||||||||||||
F1-PG-EYH![]() | F1-PG-EYH |
| Leadtime 2-3 weeks | P6-AH-3N | XFRMR ISO PWR 1KVA 4.5 9A | DU | Active | Isolated | 208V, 220V, 240V | 104V, 110V, 120V | 1000VA | Screw Terminal | Screw Terminal | ||||||||||||||
9S4J-LJB-P8![]() | 9S4J-LJB-P8 |
| Leadtime 2-3 weeks | WVJ0-UE5-BV | XFRMR AUTO 115 230V 750VA | OF | Active | Non-Isolated Autotransformer | 115V, 230V | 115V, 230V | 750VA | Wire Leads | Wire Leads | ||||||||||||||
YMXZ-PUX-3V![]() | YMXZ-PUX-3V |
| Leadtime 2-3 weeks | R6ZIZ-VX-OM5 | TRANSFORMER AUTO 115-230VAC 1KVA | 170 | Active | Non-Isolated Autotransformer | 115V, 230V | 115V, 230V | 1000VA | Wire Leads | Wire Leads | ||||||||||||||
W4-XL-RQE![]() | W4-XL-RQE |
| Leadtime 2 3 weeks | QD-QVD0-LC | TRANSFORMER ISOL | N | Active | Isolated | 115V | 115V | 100VA | Wire Leads | Wire Leads | ||||||||||||||
3YC-NRH-TX7![]() | 3YC-NRH-TX7 | Leadtime 2-3 weeks | ESPHW-QY-IB | TRANSFMR ISOL 115 TO 230VCT 1KVA | 298 | Obsolete | Isolated | 115V | 230V | 1000VA | NEMA 5-15P | - | |||||||||||||||
3ZT-0Y-FGP![]() | 3ZT-0Y-FGP |
| Leadtime 2 3 weeks | D83Q-T1-T0D | TRANSFORMER TOROIDAL ISOLATION | 178 | Active | Isolated | 120V | 120V | 1000VA | NEMA 5 15P | NEMA 5 15R 2 | ||||||||||||||
A9MW IY 05![]() | A9MW IY 05 |
| 34 | 34-CT93-ZHH | TRANSFM ISOL 115 TO 115VAC 100VA | 171 | Active | Isolated | 115V | 115V | 100VA | NEMA 5 15P | NEMA 5 15R | ||||||||||||||
MLAJR-YR0D-3J![]() | MLAJR-YR0D-3J |
| Leadtime 2-3 weeks | 0K10N-5E-45K | XFRMR ISO PWR 1KVA 4.5 9A | DU | Active | Isolated | 208V, 220V, 240V | 104V, 110V, 120V | 1000VA | Screw Terminal | Screw Terminal |