Supplier Part Number | Manufacturer Part Number | Price | Stock | Manufacturer | Description | Series | Part Status | Type | Specifications | Ratings | ||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
RT500![]() | RT500 |
| Leadtime 2-3 weeks | B97W-PRYW-TP | RECEPTACLE TESTER - USA MADE | * | Active | - | - | - | ||||||
AB4N-XD-UY![]() | AB4N-XD-UY |
| Leadtime 2-3 weeks | Q2-8T71-8Q | WIRING INSPECTOR | - | Active | GFCI, 3-Wire Circuit Tester | Tests 3-Wire Circuits and Ground Continuity | CAT II 120V | ||||||
7AM9-WKKR-6OY | 7AM9-WKKR-6OY |
| 7 | 7H-TEDJ-NYZ | DIGITAL CLAMP METER, AC AUTO-RAN | - | Active | Current Clamp Meter | DMM Functions Include Voltage, Resistance, Temperature and Current to 400A | CAT III 600V | ||||||
T+PRO![]() | T+PRO |
| Leadtime 2-3 weeks | Q6-HM-HJV | ELECTRICAL TESTER W RESISTANCE | T+ | Active | Electrical Tester, Solenoid | Measures Voltage, Resistance and Rotary Field, Tests GFCI Circuits | CAT III 1000V, CAT IV 600V | ||||||
OEL5F-5A2-IK![]() | OEL5F-5A2-IK | Leadtime 2-3 weeks | FS-TG-0TK | KIT MOTOR PHASE SEQ INDICATOR | - | Obsolete | Phase Rotation Indicator | Detects the Rotary Field of Three-Phase Systems | CAT III | |||||||
DB 1S QBK![]() | DB 1S QBK |
| Leadtime 2 3 weeks | QMM-MXJ-D0F | 1000A FLUKE 1750 THIN FLEXI 61CM | Active | Current Clamp, Probe Add On | Measures AC Current to 1000A, BNC Interface | CAT III 1000V, CAT IV 600V | |||||||
2C9-2T-6D![]() | 2C9-2T-6D |
| Leadtime 2 3 weeks | CTQ-L4RG-1X | CURRENT CLAMP AC | Active | Current Clamp, Probe Add On | Measures AC Current to 1000A, BNC Interface | CAT III 600V | |||||||
5N-BHED-CX5![]() | 5N-BHED-CX5 |
| 1 | 1BX4F-OU7D-DOP | 400A SWIVEL CLAMP | ACD | Active | Current Clamp Meter | DMM Functions Include Voltage, Resistance, Capacitance and Current to 400A | CAT III 600V | ||||||
312B![]() | 312B |
| Leadtime 2-3 weeks | KRC-VE0H-QOC | CLAMP METER 600A MINI AC MILLI A | - | Active | Current Clamp Meter | DMM Functions Include Voltage, Resistance and Current to 600A | CAT II 600V, CAT III 300V | ||||||
FLK2AC 90-1000V5PK![]() | FLK2AC 90-1000V5PK |
| Leadtime 2-3 weeks | LFFOY-AV-O5 | VOLT ALERT 90-1000V, 5 PACK | VoltAlert™ | Active | Voltage Detector | Measures AC Voltage 90 ~ 1000VAC | CAT IV 1000V | ||||||
6H-RQC-3A![]() | 6H-RQC-3A | Leadtime 2 3 weeks | G8K-BY-45 | FS3000A 6000A 4 PH 36 INCH THIN | Obsolete | Current Clamp, Probe Add On | Measures AC Current to 6000A, BNC Interface | CAT III 1000V, CAT IV 600V | ||||||||
60K-RAB-C6L![]() | 60K-RAB-C6L | 8 | 8V-2A4-EM | CLAMPMETER | - | Obsolete | Current Clamp Meter | DMM Functions Include Voltage, Resistance, Frequency and Current to 1000A | CAT III 600V | |||||||
NN58-AG3-3D1![]() | NN58-AG3-3D1 | 7 | 7PIAM-JR-WVD | TRANSDUC CLAMP-ON 600A AC DC | CT | Obsolete | Current Clamp, Probe Add On | Measures AC, DC Current to 600A, Banana Interface | - | |||||||
1212210![]() | 1212210 |
| Leadtime 2-3 weeks | JC-K7-5EY | CURRENT PLIER MULTIMETER | TESTFOX CC-1 | Active | Current Clamp Meter | Measures Voltage, Current and Resistance | CAT III 600V | ||||||
FD-K5H-WA![]() | FD-K5H-WA |
| 4 | 4SC-IF-EF1 | TESTER GROUND ROD | - | Active | Current Clamp Meter | Tests Earth Ground Continuity | CAT III 150V | ||||||
I5S![]() | I5S |
| Leadtime 2-3 weeks | LJ9BN-RQ5W-06I | CURRENT CLAMPS AC 5A | - | Active | Current Clamp, Probe Add On | Measures AC Current to 6A, BNC Interface | CAT III 600V | ||||||
DC3M-OW-JR![]() | DC3M-OW-JR |
| 3 | 3IVZ-Q5-X2 | CLAMP METER 400AC WITH TEMP | 324 | Active | Current Clamp Meter | DMM Functions Include Voltage, Resistance, Capacitance, Temperature and Current to 400A | CAT III 600V, CAT IV 300V | ||||||
7KX-1ID-LM![]() | 7KX-1ID-LM |
| Leadtime 2-3 weeks | C6-50W4-0Z8 | 1000A ACDC TRMS CLAMP MULTIMETER | 300 | Active | Current Clamp Meter | Measures AC, DC Current to 1000A, Banana Interface | CAT III 1000V, CAT IV 600V | ||||||
JX-9WYR-MH5![]() | JX-9WYR-MH5 |
| Leadtime 2-3 weeks | MU577-IOHE-5JG | DIGITAL CLAMP ON METER CAP FREQ | ACD | Active | Current Clamp Meter | DMM Functions Include Voltage, Resistance, Capacitance, Frequency and Current to 600A | CAT III 600V | ||||||
O5-GL-PMD![]() | O5-GL-PMD |
| 2 | 2Y-CW0G-B7 | DUAL RANGE HIGH VOLTAGE TESTER | * | Active | - | - | - | ||||||
25511![]() | 25511 |
| Leadtime 2-3 weeks | JW2M-QY-PSS | INSULATED SINGLE POLE VOLTAGE DE | - | Active | Voltage Detector | Measures AC Voltage 110 ~ 250VAC | - | ||||||
BY1-5JAW-5S![]() | BY1-5JAW-5S |
| 73 | 73-TBO8-BTC | FLUKE-173X IFLEXI 1500A 12 | Fluke Connect™ | Active | Current Clamp, Probe Add On | Measures AC Current to 1500A, BNC Interface | - | ||||||
S9ML3-GU2-I7Z![]() | S9ML3-GU2-I7Z | Leadtime 2-3 weeks | OYU-F07L-YJ | 3000A 1PH FLUKE 1735 & 174X | - | Obsolete | Current Clamp, Probe Add On | Measures AC Current to 3000A, BNC Interface | CAT III 1000V, CAT IV 600V | |||||||
K2NY-KL1C-R3L![]() | K2NY-KL1C-R3L |
| Leadtime 2 3 weeks | MM-7QJJ-0O | 600A AC NAVIGATOR CLAMP | Navigator™ | Active | Current Clamp Meter | DMM Functions Include Voltage, Resistance, Capacitance, Frequency and Current to 600A | CAT III 1000V, CAT IV 600V | ||||||
7LNS-CKS-G4![]() | 7LNS-CKS-G4 |
| 2 | 2R-S9IM-0ZD | DMM CLAMP-ON TRMS 2000A | ACD | Active | Current Clamp Meter | DMM Functions Include Voltage, Resistance, Capacitance, Frequency and Current to 2000A | CAT III 600V |