Supplier Part Number | Manufacturer Part Number | Price | Stock | Manufacturer | Description | Series | Part Status | Type | Specifications | Ratings | ||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
6I7M2-GU9V-3B![]() | 6I7M2-GU9V-3B |
| Leadtime 2-3 weeks | KGN-ZZJY-7F | TESTER AC DC VOLTAGE CONT IP65 | PROFIPOL | Active | Voltage Detector | Measures AC, DC Voltage 6 ~ 400VAC, 6 ~ 400VDC | - | ||||||
EN-I4FW-8OP![]() | EN-I4FW-8OP |
| Leadtime 2-3 weeks | EIBW-CK4D-E26 | CURRENT PROBE AC DC | - | Active | Current Clamp, Probe Add On | Measures AC Current to 300A, DC Current to 450A, BNC Interface | CAT III 300V | ||||||
UTR 7Z AU![]() | UTR 7Z AU | Leadtime 2 3 weeks | TYE-HEV-ND | 5000A FLUKE 1750 THIN FLEXI 61CM | Obsolete | Current Clamp, Probe Add On | Measures AC Current to 5000A, BNC Interface | CAT III 1000V, CAT IV 600V | ||||||||
DN UR BIA![]() | DN UR BIA |
| Leadtime 2 3 weeks | D1BB-01IA-7J | ACDC 1000A INDUSTRIAL CLAMP | ACDC | Active | Current Clamp Meter | DMM Functions Include Voltage, Resistance, Capacitance, Frequency and Current to 1000A | CAT III 1000V, CAT IV 600V | ||||||
TCRL-H7-8I![]() | TCRL-H7-8I | 1810 | 1810-2Q5-H81 | CLAMP METER 400AC 400OHM RES | 320 | Obsolete | Current Clamp Meter | DMM Functions Include Voltage, Resistance and Current to 400A | CAT III 600V | |||||||
ACD-15 TRMS-PRO![]() | ACD-15 TRMS-PRO |
| 9 | 9N-3M-3U | DMM CLAMP-ON TRMS 2000A | ACD | Active | Current Clamp Meter | DMM Functions Include Voltage, Resistance, Capacitance, Frequency and Current to 2000A | CAT III 600V | ||||||
FLK-CNX V3000![]() | FLK-CNX V3000 | 3987 | 3987-MX-XOT | WIRELESS AC VOLTAGE MODULE | CNX 3000 | Obsolete | Voltage Detector | Measures AC Voltage 6 ~ 1000VAC | CAT III 1000V, CAT IV 600V | |||||||
ZZ0 CJ3 FZP![]() | ZZ0 CJ3 FZP | Leadtime 2 3 weeks | XD-901-NQ | CLAMP METER 400AC 600OHM RES | 330 | Obsolete | Current Clamp Meter | DMM Functions Include Voltage, Resistance and Current to 400A | CAT III 600V | |||||||
I5A 50A CLAMP PQ4![]() | I5A 50A CLAMP PQ4 |
| Leadtime 2-3 weeks | R74-T8T-718 | 4-PHASE 5A 50A MINI CURRENT CLAM | - | Active | Current Clamp, Probe Add On | Measures AC Current to 50A, BNC Interface | CAT III 600V | ||||||
SGA1A-5V-6R![]() | SGA1A-5V-6R |
| Leadtime 2-3 weeks | J9DQ0-HG4-FRN | 600A TRMS AC DC CLAMP | Fluke Connect™ | Active | Current Clamp Meter | DMM Functions Include Voltage, Resistance, Capacitance, Frequency and Current to 600A | CAT III 1000V, CAT IV 600V | ||||||
CM-86WU-L6![]() | CM-86WU-L6 | Leadtime 2-3 weeks | N406Z-9X-6DB | CLAMP METER 1000AC W FREQUENCY | 330 | Obsolete | Current Clamp Meter | DMM Functions Include Voltage, Resistance, Frequency and Current to 1000A | CAT III 600V | |||||||
FTN-YSRQ-F2 | FTN-YSRQ-F2 |
| Leadtime 2-3 weeks | R8-AYNV-ZIS | DIGITAL CLAMP METER, AC AUTO-RAN | - | Active | Current Clamp Meter | DMM Functions Include Voltage, Resistance, Capacitance, Temperature, Frequency and Current to 600A | CAT III 1000V, CAT IV 600V | ||||||
V83-HLU-OU![]() | V83-HLU-OU |
| Leadtime 2-3 weeks | XR-GDQ6-H81 | VOLTAGE TESTER | PY | Active | Voltage Detector | Measures AC, DC Voltage 120 ~ 480VAC, 160 ~ 600VDC | CAT III 600V | ||||||
ECB50A![]() | ECB50A |
| Leadtime 2-3 weeks | YKXCN-T6BG-WW | CIRC BRKR LOC AND AC LINE TRACER | - | Active | Wire Tracer | Identifies Breakers, Open Circuits and Pinouts in Various Cable Types | CAT III 150V | ||||||
K8-ND-USW![]() | K8-ND-USW | Leadtime 2-3 weeks | MTOJ-34KJ-NJ | ADAPTER 400A AC CURRENT | - | Obsolete | Current Clamp, Probe Add On | Measures AC Current to 400A, Banana Interface | CAT II 600V, CAT III 300V | |||||||
FLON8-70L-6AC![]() | FLON8-70L-6AC | Leadtime 2-3 weeks | HFN-KFL-UU | TRUE RMS HVAC CLAMP METER | - | Obsolete | Current Clamp Meter | Measures Voltage, Current, Resistance, Capacitance and Temperature | CAT III 600V | |||||||
DC3M-OW-JR![]() | DC3M-OW-JR |
| 1 | 1L-17-4X | CLAMP METER 400AC WITH TEMP | 324 | Active | Current Clamp Meter | DMM Functions Include Voltage, Resistance, Capacitance, Temperature and Current to 400A | CAT III 600V, CAT IV 300V | ||||||
AT-2003![]() | AT-2003 | Leadtime 2-3 weeks | GR-6XWD-UH3 | WIRE TRACR PROF OPN TRCR SYS | AT | Obsolete | Wire Tracer | Identifies Breakers, Open Circuits and Pinouts in Various Cable Types | - | |||||||
ORV5 S3I 4P![]() | ORV5 S3I 4P |
| Leadtime 2 3 weeks | DH-V6-9GF | VOLTAGE DETECTOR NON CONTACT | VP | Active | Voltage Detector | Measures AC Voltage 110 ~ 1000VAC | CAT III 1000V | ||||||
291![]() | 291 |
| Leadtime 2-3 weeks | H8-I01-34R | MANUAL DGTL CLAMP W TEST LEADS | - | Active | Current Clamp Meter | DMM Functions Include Voltage, Resistance and Current to 700A | CAT III 600V | ||||||
BSZC 2FK ACQ![]() | BSZC 2FK ACQ |
| Leadtime 2 3 weeks | DBNZ-BQO7-8MY | DC CLAMP METER 99.9MA | Fluke Connect™ | Active | Current Clamp Meter | Measures DC Current to 99.9mA, Banana Interface | |||||||
C0Z49-HS-CY6![]() | C0Z49-HS-CY6 |
| Leadtime 2 3 weeks | H3-461A-4HN | VOLTAGE TESTER | PY | Active | Voltage Detector | Measures AC, DC Voltage 120 ~ 480VAC, 160 ~ 600VDC | CAT III 600V | ||||||
LN-96-7M![]() | LN-96-7M |
| Leadtime 2 3 weeks | JG-WU-E1 | 600A AC NAVIGATOR CLAMP | Navigator™ | Active | Current Clamp Meter | DMM Functions Include Voltage, Resistance, Capacitance, Frequency and Current to 600A | CAT III 1000V, CAT IV 600V | ||||||
ZQ00-YL6-Q1U![]() | ZQ00-YL6-Q1U |
| 37 | 37XH-N2MO-QPU | 1750 40A CURRENT CLAMP | 1750 | Active | Current Clamp, Probe Add On | Measures AC Current to 40A, BNC Interface | CAT III 600V | ||||||
2Z9VR OL WH4![]() | 2Z9VR OL WH4 | 9 | 9H6-43RL-88 | 200 1000A FLUKE 1760 | Obsolete | Current Clamp, Probe Add On | Measures AC Current to 1000A, BNC Interface | CAT IV 600V |